CHROMA 6314 PDF

The Chroma A W and A W DC electronic load mainframes accept the user-installable A series load modules for easy system. RENT CHROMA DC Electronic Load Mainframe. Chroma Model DC Electronic Load Mainframe is suitable for the test and evaluation of multi-output. Product Name: DC Electronic Load. Model Name: , , , , , , , , , Manufacturer’s Name: Chroma ATE .

Author: Dourg Fekinos
Country: Suriname
Language: English (Spanish)
Genre: Art
Published (Last): 18 November 2013
Pages: 335
PDF File Size: 3.78 Mb
ePub File Size: 18.51 Mb
ISBN: 553-6-91638-989-5
Downloads: 73480
Price: Free* [*Free Regsitration Required]
Uploader: Dijar

Any comment or help is appreciated especially if you have used this dummy load before.

Message 2 of 7. The figure below shows the programmable parameters of the A modules:. The has self-diagnosis routine to maintain instrumental 63314 all the time.

LED Load Simulator | Chroma ATE Inc.

Each model is designed with specific applications in mind. Use data flow instead! Real time measurement of voltage, current, is integrated into each load module using a bit precision measurement circuit.

Parallel Control The A provides parallel control, which enables high power testing when a single cjroma cannot meet the requirement of high power applications. As a constant current source, the LED driver has an output voltage range with a constant output current. What can i do to improve my program?

Please contact us via email or toll free at and we will be happy to assist you with this request. Additionally, the offers an optional remote controller for automated production line.

Then you can start to program. The system is configured by plugging the user selectable load modules into the system mainframe, and operated using the keypad on the front panel of chroam instrument or the remote controlled instructions via RS or GPIB interface. The A series can chroa a wide range of dynamic loading applications. Most Active Software Boards: Equipment Offer Sent Your offer has been sent to our sales department for review.

  ISTORIJA HELENSKE KNJIZEVNOSTI PDF

If my VISA Write and Read works fine when i want to fetch voltage and current, shouldnt i be able to control the machine by putting: The family offers 8 types of load modules ranging from model with watts power to model with watts power. Single Channel V, A, W. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type.

Unable to Process Request Your offer was received but we are unable to process it for the following reason: The user can perform on line voltage measurements and adjustments or simulate short circuit test using the user friendly keypad on the front panel.

I am currently using VISA attached but my program doesnt cbroma the load. The user can perform on line voltage measurement and adjustment, or simulate short circuit test using the simple keypad on the front panel. Dynamic Loading and Control Xhroma A loads offer high speed, programmable dynamic load simulation and control capability.

Chroma for sale $ | In Stock | AccuSource Electronics

The user interfaces include an ergonomically designed user friendly keypad on the front panel and the following computer interfaces: The A comes with RS as standard for remote control and automated testing applications.

We will notify you as soon as this item is available for purchase. Also – even if you just use raw serial commands – you never configure the serial port to have the right parameters e. In addition, up to sets of system operating status can be stored in EEPROM and recalled instantly for automated testing applications.

Chroma 6314 DC Electronic Load Mainframe With Manual O1

From figures 2 and 3, the start up voltage and current of the LED driver is very similar. These are the commands given in the manual book. Correct Issue Close Wizard. For example, the test of a battery charger can be simulated easily by setting the load to operate in constant voltage. The system is configured by plugging the user selectable load modules into the system mainframe. When using a resistor as loading, the V-I curve chroka the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1.

  KODA TADASHI PDF

Add to Inquiry Cart Data Sheet. Because all that is stated in the labVIEW program i have written is already all the things i think are feasible when reading the manual. The A series will automatically detect the OCP point, chhroma it an ideal solution for design verification as well as production line testing.

We would also greatly appreciate chromw if you could provide us with this error code: The load can be xhroma in constant current, constant voltage, and constant resistance. Furthermore, up to sets of system operating status can be stored in EEPROM and recalled instantly for automated testing application. Offer AccuSource Electronics is always happy to consider reasonable offers on our test instruments. LED drivers are usually tested in one of the following ways: Message 5 of 7.